Skip to content

Planning project · Planning application

Retaining wall in hillside development approved for single-lot residential site

City staff approved a retaining wall on a 0.32-acre residential lot in a hillside development area. The project was filed June 27, 2025, and approved administratively on Jan. 2, 2026.

ApprovedPLN25-00537Filed June 27, 20254430 W Quail Point Ct+1 related filing
Site plan for Retaining wall in hillside development approved for single-lot residential site
Site plan from the application documents.
Pin at the reported location; the shaded outline is the primary parcel (Ada County).

About this application

Retaining Wall in Hillside Development

Project name on file: 4430 W QUAIL POINT CT

Timeline

  1. Two days ago

    6 documents added

  2. Jan. 2, 2026

    Planning Applications: Project Entitled

  3. Jan. 2, 2026

    Pending Application Submittal: Planning Applications in Review

  4. July 1, 2025

    Planning Applications: Additional CR Needed

  5. July 1, 2025

    Pending Application Submittal: Start Additional IDR

  6. July 1, 2025

    Pending Application Submittal: Planning Applications in Review

  7. July 1, 2025

    IDR Review Complete: IDR Complete

  8. July 1, 2025

    Concept Review Complete: CR Complete - Type 2

  9. June 27, 2025

    Concept Review Complete: Engineering Preview

  10. June 27, 2025

    Concept Review Complete: Engineering Preview Complete

    A determination has been made that this project will be a Category II Hillside project due to the nature of surrounding slopes. In addition to the already submitted documents, additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a geotechnical report with a global slope stability analysis; structural calculations for any retaining wall that is greater than four feet of height; more than one retaining wall when the horizontal interior distance between the retaining walls is less than 10 feet and the total of all retaining walls exceeds four feet in height; a retaining wall having a surcharge; or having a backslope greater than three feet horizontal to one foot vertical (the proposed meets at least two); additional information of the existing drain pipe system (ie outfall location, functionality) that the new system will be connecting too; complete proposed contouring as the proposed slope percentages do not match the remaining existing contours.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org or we can set up a meeting if you prefer.

  11. June 27, 2025

    Application Submittal: Online

  12. June 27, 2025

    Application filed

Documents

Plans

Project narrative

Other documents

  • PDS-Concept Review Summary Report -

    July 1, 2025 · 444 KB · PDS-Concept Review Summary Report

  • PDS-Concept Review Summary Report -

    July 1, 2025 · 444 KB · PDS-Concept Review Summary Report

  • PDS-Application

    June 27, 2025 · 154 KB · PDS-Application