Planning project · Planning application
Pool and retaining walls sought for hillside home site, application expires
The application, filed Nov. 19, 2025, asked for administrative review of a pool and retaining walls on a 0.9-acre residential lot in the hillside overlay. Its status is now listed as expired.
About this application
Pool and Retaining Walls in the Hillside overlay
Project name on file: 1936 S WINDSTAR PL
Timeline
June 30, 2026
Project Cancellation: Expired
Expire PLN, no longer needed per Scott Gifford
Dec. 2, 2025
Concept Review Complete: CR Complete - Type 2
Nov. 21, 2025
Concept Review Complete: Engineering Preview
Nov. 21, 2025
Concept Review Complete: Engineering Preview Complete
A determination has been made that this project will be a Category II Hillside project due to the nature of surrounding slopes. In addition to the already submitted documents, additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN ); structural calculations for any retaining wall that is greater than four feet of height, more than one retaining wall when the horizontal interior distance between the retaining walls is less than 10 feet and the total of all retaining walls exceeds four feet in height, a retaining wall having a surcharge, or having a backslope greater than three feet horizontal to one foot vertical (these requirements will be assessed again at the time of occupancy); and civil plans.NOTE: The hazards of developing and building on property, especially in the Boise foothills, is well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org or we can set up a meeting if you prefer.
Nov. 19, 2025
Application Submittal: Online
Nov. 19, 2025
Application filed
Documents
Other documents
- PDS-Concept Review Summary Report -
Dec. 2, 2025 · 454 KB · PDS-Concept Review Summary Report
- PDS-Agency Comments - HILLSIDE RETAINING WALL PERMITTING_OCTOBER2025
Nov. 21, 2025 · 804 KB · PDS-Agency Comments
- PDS-Application
Nov. 19, 2025 · 159 KB · PDS-Application
- PDS-Other Small Docs - HILLSIDE QUESTIONAIRE
Nov. 19, 2025 · 701 KB · PDS-Other Small Docs
- PDS-Other Small Docs - IMAGE OF BACKYARD. THE POOL WILL BEGIN NEAR THE BASE OF THE ROCK AND BE ELEVATED OUT OF THE GROUND APPROXIMATELY 2.5 FEET.
Nov. 19, 2025 · 693 KB · PDS-Other Small Docs
- PDS-Other Small Docs - IMAGE OF BACKYARD. THE POOL WILL BEGIN NEAR THE BASE OF THE ROCK AND BE ELEVATED OUT OF THE GROUND APPROXIMATELY 2.5 FEET.
Nov. 19, 2025 · 638 KB · PDS-Other Small Docs
- PDS-Other Small Docs - SITE PLAN
Nov. 19, 2025 · 253 KB · PDS-Other Small Docs