Planning project · Planning application
Backyard sport pool on foothills hillside lot approved
City staff approved a 20-by-40-foot swimming pool, 5 feet deep, on a 0.52-acre residential lot classed as a hillside project. Geotechnical review, a sewer cleanout for draining and a subgrade inspection will be required during construction.

About this application
Pool
Project name on file: 2612 E PLATEAU DR
Timeline
May 1, 2026
Planning Applications: Project Entitled
Feb. 3, 2026
Pending Application Submittal: Planning Applications in Review
Feb. 2, 2026
Concept Review Complete: Engineering Preview
Feb. 2, 2026
Concept Review Complete: Engineering Preview Complete
A determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents, additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall that is greater than four feet of height, more than one retaining wall when the horizontal interior distance between the retaining walls is less than 10 feet and the total of all retaining walls exceeds four feet in height, a retaining wall having a surcharge, having a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans.Additionally, Hillside policy requires that the drain system for the pool/spa/hot tub has access to a sanitary sewer clean out for pumping to said service if it needs to be drained for any purpose as draining onto the ground or into any storm drain system is prohibited. Provide clean out location and callouts on the plans.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted and accepted by PW Hillside before scheduling your inspection with the Building Department.NOTE: The hazards of developing and building on property, especially in the Boise foothills, is well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org or we can set up a meeting if you prefer.
Feb. 2, 2026
Concept Review Complete: CR Complete - Type 2
Jan. 28, 2026
Application Submittal: Online
Jan. 28, 2026
Application filed
Documents
Site plans
- Download Pool site plan with enlarged pool, details and equipment sheets
Site plan for a 20 x 40 ft inground swimming pool, with enlarged pool plan, step and sunshelf sections, and pool equipment sheet, dated 11-21-2025.
Jan. 28, 2026 · 4 pages · 678 KB · PDS-Other Small Docs
Project narrative
- Download Concept review summary report
Planner notes classify the project as a Category II hillside project and list the geotechnical, retaining wall, pool drainage and civil plan documents expected next.
Feb. 2, 2026 · 2 pages · 451 KB · PDS-Concept Review Summary Report
Application
- Download Planning project application form
Application for an inground concrete sport pool (20x40x5 ft) with automatic safety cover, paver patio, deck drains and pool equipment, filed by a construction company.
Jan. 28, 2026 · 2 pages · 158 KB · PDS-Application
- Download PDS-Other Small Docs - HILLSIDE QUESTIONNAIRE (COMPLETED).
Jan. 28, 2026 · 1 page · 688 KB · PDS-Other Small Docs
Correspondence
- Download Hillside retaining wall permitting guidance
Public Works guidance on when retaining walls in the hillside zone need a determination, slope stability analysis, and planning-code height and setback limits.
Feb. 2, 2026 · 5 pages · 804 KB · PDS-Agency Comments