Skip to content

Planning project · Planning application

Homeowner seeks city guidance on two terraced retaining walls, stairs and patio

A single-family homeowner filed a pre-application concept for two retaining walls no taller than 4 feet, a stairway, a paved patio and landscaping on a sloped yard. No new home or addition is proposed. The city is reviewing it at the concept stage.

In reviewPLN26-00938Filed Oct. 10, 2026Highlands · 415 E Curling Dr
Site plan for Homeowner seeks city guidance on two terraced retaining walls, stairs and patio
Site plan from the application documents.
Pin at the reported location; the shaded outline is the primary parcel (Ada County).

About this application

No description has been published for this record yet.

Project name on file: 415 E CURLING DR

Timeline

  1. Today

    Status changed from “Engineering Preview” to “Concept Review”

  2. Today

    Concept Review Complete: Notes

    empirenurseryhardscape@outlook.com was added as an additional authorized user

  3. Today

    Concept Review Complete: Engineering Preview Complete

    Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents (please submit them with subsequent applications), additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org. Please include your application number and address in the subject line.

  4. Today

    Document added: PDS-Agency Comments - HILLSIDE RETAINING WALL PERMITTING_OCTOBER2025

  5. Yesterday

    Status changed from “Concept Review” to “Engineering Preview”

  6. Yesterday

    Concept Review Complete: Engineering Preview

  7. Two days ago

    4 documents added

  8. Oct. 10, 2026

    Application Submittal: Online

  9. Oct. 10, 2026

    Application filed

Documents

Site plans

Project narrative

Application

Other documents

  • PDS-Agency Comments - HILLSIDE RETAINING WALL PERMITTING_OCTOBER2025

    Today · 804 KB · PDS-Agency Comments

  • Public Works questionnaire answering whether the project involves new grading over 12 inches deep and retaining walls, including wall height and spacing details.

    Oct. 10, 2026 · 1 page · 702 KB · PDS-Other Small Docs

    Download Hillside project questionnaire

Nearby

The Boise Builds daily briefing

Every new planning application in Boise, and every filing that changed, in one email each morning. See a sample