One single-family home proposed on 1.5-acre hillside lot

The application seeks city approval to build one house on a hillside site of about 1.5 acres. City staff say it needs the stricter Category II hillside review because of surrounding slopes, and a geotechnical report may be required. It is under administrative review.

In reviewPLN25-01126Filed Dec. 19, 2025Highlands · 799 E Chardie Rd+1 related filing
Site plan for One single-family home proposed on 1.5-acre hillside lot
Site plan from the application documents.
Pin at the reported location; the shaded outline is the primary parcel (Ada County).

About this application

Hillside for Single-Family Home

Project name on file: 799 E CHARDIE RD

Timeline

  1. Two days ago

    5 documents added

  2. Sept. 1, 2026

    Pending Application Submittal: Planning Applications in Review

  3. July 15, 2026

    Planning Applications: Generate Additional Application

    Regenerate CFH as the original CFH invitation went to the wrong applicant, due to two contacts showing as "Applicant". Regenerated to go to Rodney.

  4. Jan. 12, 2026

    Concept Review Complete: CR Complete - Type 2

  5. Dec. 23, 2025

    Concept Review Complete: Engineering Preview Complete

    PW Hillside would like to schedule a meeting as soon as possible to discuss in further detail the following determination and our expectations. Please contact us at HillsideDrainage@cityofboise.org to schedule.A determination has been made that this project will be a Category II Hillside project due to the nature of surrounding slopes. In addition to the already submitted documents, additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a geotechnical report with a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall that is greater than four feet of height, more than one retaining wall when the horizontal interior distance between the retaining walls is less than 10 feet and the total of all retaining walls exceeds four feet in height, a retaining wall having a surcharge, or having a backslope greater than three feet horizontal to one foot vertical (these requirements will be assessed again at the time of occupancy); and civil plans.NOTE: The hazards of developing and building on property, especially in the Boise foothills, is well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.

  6. Dec. 23, 2025

    Concept Review Complete: Corrections Required

    Please upload a project description.

  7. Dec. 22, 2025

    Concept Review Complete: Corrections Required

    Upload documents and drawings.

  8. Dec. 22, 2025

    Concept Review Complete: Engineering Preview

  9. Dec. 19, 2025

    Application Submittal: Online

  10. Dec. 19, 2025

    Application filed

Documents

Site plans

  • Site concept drawing showing lot layout, setbacks, topography, retaining walls, driveway and courtyard, with fill, cut, wall, asphalt and concrete quantities.

    Dec. 22, 2025 · 3 pages · 2.1 MB · PDS-Other Small Docs

    Download Proposed site plan with grading and earthwork totals

Project narrative

  • Advisory concept review for a single-family home on a hillside site, noting a Category II Hillside determination and expected geotechnical, retaining wall, and civil plan documents.

    Jan. 12, 2026 · 2 pages · 452 KB · PDS-Concept Review Summary Report

    Download Concept review summary report

Application

  • Application for a single-family home of about 5,000 sq ft with a pool in an A-1 zone, including a Hillside Questionnaire requirement and owner-signed certification.

    Dec. 19, 2025 · 2 pages · 158 KB · PDS-Application

    Download Planning project application form

Correspondence

Other documents