Skip to content

Planning project · Planning application

Block retaining wall proposed to replace railroad tie wall on hillside lot

The city treats the project as a Category II hillside review because of slope and unstable soils. A geotechnical report and engineering plans may be required. Staff would decide the application administratively.

SubmittedPLN26-00760Filed Aug. 12, 2026488 W Sandstone Ct+1 related filing
Site plan for Block retaining wall proposed to replace railroad tie wall on hillside lot
Site plan from the application documents.
Pin at the reported location; the shaded outline is the primary parcel (Ada County).

About this application

Cat II

Project name on file: 488 W SANDSTONE CT

Timeline

  1. Two days ago

    10 documents added

  2. Aug. 18, 2026

    Concept Review Complete: Engineering Preview

  3. Aug. 18, 2026

    Concept Review Complete: Engineering Preview Complete

    Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents (please submit them with subsequent applications), additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org. Please include your application number and address in the subject line.

  4. Aug. 18, 2026

    Concept Review Complete: CR Complete - Type 2

  5. Aug. 14, 2026

    Concept Review Complete: Hillside Questionnaire Needed

  6. Aug. 12, 2026

    Application Submittal: Online

  7. Aug. 12, 2026

    Application filed

Documents

Plans

Project narrative

Application

Photos

Correspondence

Other documents

  • PDS-Other Small Docs - PUBLIC WORKS HILLSIDE QUESTIONNAIRE 08/17/26

    Aug. 17, 2026 · 154 KB · PDS-Other Small Docs

  • PDS-Other Small Docs - DIFFERENT WALL OF EXISTING ANGEL TO BE REPLACED.

    Aug. 12, 2026 · 12.1 MB · PDS-Other Small Docs

  • PDS-Other Small Docs - LANDSCAPING DESIGN SHOWING WALLS AND PAVER PATIO.

    Aug. 12, 2026 · 3.2 MB · PDS-Other Small Docs

  • PDS-Other Small Docs - RAILROAD TIE WALL WITH FENCE ON TOP. FUTURE FENCE TO BE BEHIND BLOCK WALL.

    Aug. 12, 2026 · 9.6 MB · PDS-Other Small Docs

Nearby

The Boise Builds daily briefing

Every new planning application in Boise, and every filing that changed, in one email each morning. See a sample