Planning project · Planning application
Detached garage with apartment above and new retaining wall proposed at single-family home
The plan adds one accessory dwelling unit atop a new detached garage on a 0.28-acre lot and replaces a retaining wall. It revives a project whose earlier approvals expired, and it needs hillside review and a Hearing Examiner decision.

About this application
Garage w/ADU and replace retaining wall
Project name on file: 214 W CIRCLE WAY DR
Timeline
Two days ago
11 documents added
Sept. 4, 2026
IDR Review Complete: IDR Waived
Sept. 4, 2026
Neighborhood Meeting Review: Completed
Aug. 18, 2026
Concept Review Complete: CR Complete - Type 3
Aug. 14, 2026
Concept Review Complete: Engineering Preview Complete
Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents (please submit them with subsequent applications), additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org. Please include your application number and address in the subject line.
Aug. 13, 2026
Concept Review Complete: Engineering Preview
This application was previously approved under PLN24-00618 and expired. Planning has decided to apply the previous conditions of approval to this new application. However, we would like to request a new Hillside Engineering Review.
July 30, 2026
Application Submittal: Online
July 30, 2026
Application filed
Documents
Site plans
- Download PDS-Other Small Docs - PREVIOUSLY SUBMITTED SITE PLAN
July 30, 2026 · 1 page · 1.9 MB · PDS-Other Small Docs
Plans
- Download PDS-Other Small Docs - PREVIOUSLY SUBMITTED GRADING PLAN.
July 30, 2026 · 1 page · 1.5 MB · PDS-Other Small Docs
- Download PDS-Other Small Docs - PREVIOUSLY SUBMITTED LANDSCAPE PLAN
July 30, 2026 · 1 page · 15.3 MB · PDS-Other Small Docs
- Download PDS-Other Small Docs - PREVIOUSLY SUBMITTED LANDSCAPING PLAN
July 30, 2026 · 1 page · 15.3 MB · PDS-Other Small Docs
Project narrative
- Download PDS-Concept Review Summary Report -
Aug. 18, 2026 · 3 pages · 463 KB · PDS-Concept Review Summary Report
- Download PDS-Other Small Docs - INITIAL PERMITS HAVE EXPIRED. THIS PROJECT DESCRIPTIONS DESCRIBES THE CONTINUATION OF A PREVIOUSLY PERMITTED PROJECT- CVA23-00015
July 30, 2026 · 1 page · 30 KB · PDS-Other Small Docs
- Download PDS-Other Small Docs - PROJECT DESCRIPTION
July 30, 2026 · 1 page · 30 KB · PDS-Other Small Docs
Notices
- Download PDS-Other Small Docs - COMPLETED NEIGHBORHOOD MEETING DOCS.
Sept. 3, 2026 · 14 pages · 13.8 MB · PDS-Other Small Docs
Application
- Download PDS-Application
July 30, 2026 · 2 pages · 154 KB · PDS-Application
- Download PDS-Other Small Docs - PUBLIC WORKS HILLSIDE PROJECT QUESTIONNAIRE
July 30, 2026 · 1 page · 153 KB · PDS-Other Small Docs
Correspondence
- Download PDS-Agency Comments - HILLSIDE RETAINING WALL PERMITTING_OCTOBER2025
Aug. 14, 2026 · 5 pages · 804 KB · PDS-Agency Comments