Planning project · Planning application
Single-family home on 0.31-acre hillside lot approved
City staff approved plans for one single-family home on a 0.31-acre lot in the Hillside area. The application, filed May 27, included grading plans and a geotechnical report. The decision was made Sept. 30.

About this application
Single-family home in Hillside
Project name on file: 4691 N ACCIPITER PL
Timeline
Aug. 24, 2026
Planning Applications: Project Entitled
June 9, 2026
Pending Application Submittal: Planning Applications in Review
June 8, 2026
Concept Review Complete: CR Complete - Type 2
June 2, 2026
Concept Review Complete: Corrections Required
Maximum driveway width in the front setback may not exceed 30' wide. Please provide a site plan that meets this requirement.
May 28, 2026
Concept Review Complete: Engineering Preview Complete
Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents, additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org or we can set up a meeting if you prefer.
May 27, 2026
Concept Review Complete: Engineering Preview
May 27, 2026
Application Submittal: Online
May 27, 2026
Application filed
Documents
Site plans
- Download Site plan for new single-family home
Site plan with general notes, setbacks, energy compliance notes and foundation notes for a new attached-garage home in an existing subdivision lot.
May 27, 2026 · 7 pages · 2.9 MB · PDS-Other Small Docs
Plans
- Download Grading and drainage construction details
Detail sheet with grading and drainage notes, including foundation drain, roof drain, side yard conveyance, expansion joint, and cleanout details, referencing the geotechnical report.
June 5, 2026 · 1 page · 675 KB · PDS-Other Small Docs
- Download Grading plan
Site grading plan showing existing and proposed contours, drainage features, and numbered callout notes on erosion control, roof and foundation drains, and driveway and patio work.
June 5, 2026 · 1 page · 874 KB · PDS-Other Small Docs
Application
- Download Planning project application form
Application for a new single-family residence on an R-1A zoned parcel, with applicant, owner, and zoning details listed; it references a required Hillside Questionnaire.
May 27, 2026 · 2 pages · 158 KB · PDS-Application
Studies and reports
- Download Limited deep geotechnical evaluation for Subdivision No. 11 lots
Idaho Native Geotech's limited deep subsurface evaluation of several lots in Eyrie Canyon Subdivision No. 11, reviewing prior ALLWEST geotechnical reports and addenda.
May 27, 2026 · 32 pages · 1.9 MB · PDS-Other Small Docs
Other documents
- PDS-Other Small Docs - MANUAL J
June 9, 2026 · 913 KB · PDS-Other Small Docs
- PDS-Concept Review Summary Report -
June 8, 2026 · 470 KB · PDS-Concept Review Summary Report
- PDS-Agency Comments - HILLSIDE RETAINING WALL PERMITTING_OCTOBER2025
May 28, 2026 · 804 KB · PDS-Agency Comments
- PDS-Other Small Docs - 05272026_HILLSIDE QUESTIONNAIRE
May 27, 2026 · 688 KB · PDS-Other Small Docs