Development review · Planning application
Water treatment building for municipal well approved in Meridian
The city approved a new treatment building with a filtration system and pumping upgrades for an existing groundwater well. It is meant to remove minerals that affect water quality so the well can serve as a primary source. The site covers 0.23 acres.
From the filing
The application's description as it appears in City of Meridian's record. See the official record
This project consists of designing and constructing a new water treatment facility to improve the quality and reliability of an existing municipal groundwater well (Well 24). The improvements focus on removing naturally occurring minerals that cause aesthetic issues, allowing the well to serve as a primary water source. Key components include installation of a filtration system, upgrades to pumping capacity, construction of a new treatment building, and integration of chemical, electrical, and control systems. Additional site improvements such as piping, drainage, access, and security enhancements are included to support efficient long-term operation. Upon completion, the project will provide consistent delivery of higher-quality water to the distribution system and enhance overall system performance.
Project name on file: Well 24 Treatment Building
Timeline
July 24, 2026
GIS Review: Approved
July 14, 2026
MFD Plan Review: No Comment
July 13, 2026
MPD Review: No Comment
July 9, 2026
Planning Review: Approved
July 1, 2026
Wastewater Modeling Review: Approved
June 30, 2026
ACHD Review: Approved
June 30, 2026
Transportation Plan Review: No Comment
June 30, 2026
Water Modeling Review: Approved
June 30, 2026
GIS Review: More Information Required
June 30, 2026
Land Development Review: No Comment
June 29, 2026
Floodplain Review: FLDP Not Required
June 29, 2026
Application Submittal: Accepted
June 23, 2026
Application Submittal: More Information Required
Any highlighted checklist item above is required unless pre-authorized by a planner. If it is determined that a checklist item is not required, list the missing item(s) and planner’s name in the project description field in Accela.Trash Enclosure Approval*Photometric PlanRecorded PlatPublic Utility PlanVicinity map
June 10, 2026
Application Submittal: More Information Required
Please provide all drawings and documents, as required by Submittal Standards located at https://meridiancity.org/community-development/planning/current-planning/applications-and-checklists/. Your Submittal is missing the following drawings/documents: Narrative, Warranty Deed, Affidavit of Legal Interest, Landscape Plan, AutoCad file, ASM checklist and Public Utility Plan. If a planner has told you that any of these items are not required, please state the planner's name and the items that are not required. The items that I have been uploaded, are the building plans. All can be deleted except the Site Plan and Elevations Plans. Please then upload the items in the previous comment.
June 10, 2026
Application filed
Documents
No documents have been published for this record yet.