Skip to content

Planning project · Planning application

Single-family home proposed on hillside lot of about a quarter acre

The application asks the city to approve one single-family house on a 0.27-acre hillside lot. City staff are reviewing it administratively, so no public hearing is listed.

In reviewPLN26-00860Filed Sept. 17, 2026Warm Springs Mesa · 3638 E Asteroid Ct+1 related filing
Site plan for Single-family home proposed on hillside lot of about a quarter acre
Site plan from the application documents.
Pin at the reported location; the shaded outline is the primary parcel (Ada County).

From the filing

The application's description as it appears in City of Boise's record. See the official record

SFD in Hillside

Project name on file: 3638 E ASTEROID CT

Timeline

  1. Oct. 13, 2026

    6 documents added

  2. Oct. 5, 2026

    Pending Application Submittal: Planning Applications in Review

  3. Sept. 30, 2026

    Concept Review Complete: CR Complete - Type 2

  4. Sept. 29, 2026

    Concept Review Complete: Corrections Required

    Please label the width of the driveway.

  5. Sept. 24, 2026

    Concept Review Complete: Engineering Preview

  6. Sept. 24, 2026

    Concept Review Complete: Engineering Preview Complete

    Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents (please submit them with subsequent applications), additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org. Please include your application number and address in the subject line.

  7. Sept. 18, 2026

    Concept Review Complete: Hillside Questionnaire Needed

  8. Sept. 17, 2026

    Application Submittal: Online

  9. Sept. 17, 2026

    Application filed

Documents

Site plans

  • Planner's advisory summary for a single-family dwelling proposal, classifying the project as a Category II Hillside project and listing additional geotechnical, structural, and civil documents expected.

    Sept. 30, 2026 · 2 pages · 452 KB · PDS-Concept Review Summary Report

    Download Concept review summary report
  • Revised site plan for a new residence showing setbacks, driveway, patio, garage and fence locations, with dimensions and a scale of 1 inch to 5 feet.

    Sept. 29, 2026 · 1 page · 653 KB · PDS-Other Small Docs

    Download Revised site plan with driveway dimensions
  • Cover sheet with general notes, abbreviations, sheet index and area tallies for a single-family residence, including total livable area and lot coverage.

    Sept. 17, 2026 · 1 page · 1.2 MB · PDS-Other Small Docs

    Download Site plan with lot coverage and square footage notes

Application

  • Public Works questionnaire marking a new dwelling structure as part of the project, with questions on retaining walls over 4 feet and closely spaced multiple walls.

    Sept. 21, 2026 · 1 page · 678 KB · PDS-Other Small Docs

    Download Public Works hillside project questionnaire
  • Application for a new single-family home on an R-1A zoned lot, with a required Hillside Questionnaire referenced.

    Sept. 17, 2026 · 2 pages · 154 KB · PDS-Application

    Download Planning project application form

Correspondence

  • Public Works guidance on when retaining walls in the hillside zone need a determination, slope stability analysis, and planning-code height and setback limits.

    Sept. 24, 2026 · 5 pages · 804 KB · PDS-Agency Comments

    Download Hillside retaining wall permitting guidance

Nearby

The Boise Builds daily briefing

Every new planning application in the Treasure Valley, and every filing that changed, in one email each morning. See a sample

Free. One email a day, only when something is new. Unsubscribe anytime.