Planning project · Planning application
172-square-foot addition and two rebuilt decks proposed for hillside home
The plan would enlarge an existing single-family house and rebuild two decks in the city's hillside area. City staff say it needs a more detailed hillside review because of slope and soil concerns. The application is under administrative review.

From the filing
The application's description as it appears in City of Boise's record. See the official record
Hillside
Project name on file: 1415 E FORT ST
Timeline
Oct. 13, 2026
6 documents added
Oct. 8, 2026
Pending Application Submittal: Planning Applications in Review
Oct. 5, 2026
Concept Review Complete: CR Complete - Type 2
Aug. 11, 2026
Concept Review Complete: Engineering Preview
Aug. 11, 2026
Concept Review Complete: Engineering Preview Complete
Based on submitted documents and limited overview of the property, a determination has been made that this project will be a Category II Hillside project due to slope, erosion-prone soils, unstable soils, earth movement, and other geologic and hydrologic hazards. In addition to the already submitted documents (please submit them with subsequent applications), additional documents may be required during the CFH Review process.Additional documents that you can expect to provide will be a site-specific geotechnical report with the possibility of a global slope stability analysis (please see the Agency Comment for Hillside Retaining Wall Permitting within this PLN); structural calculations for any retaining wall system that is greater than four feet in height from top of foundation to top of wall, that has more than one wall when the interior horizontal distance between the walls is less than 10 feet and the total height of all walls exceeds four feet, that has a surcharge, that has a backslope greater than three feet horizontal to one foot vertical, or that has structural components (these requirements will be assessed again at the time of occupancy); and civil plans. Please refer to the Hillside Development Requirements for Technical Reports for grading & drainage plan and geotechnical report requirements.A subgrade inspection by a geotechnical firm will be required at the time of construction once the subgrade is exposed and prior to placement of foundation materials or forms/rebar. A report of the inspection will need to be submitted to and accepted by PW Hillside (HillsideDrainage@cityofboise.org) before scheduling your inspection with the Building Department and receiving final occupancy.NOTE: The hazards of developing and building on a property, especially in the Boise foothills, are well known. It is the responsibility of the applicant/owner’s design, geological, and engineering professionals, not the City, to identify, address, and mitigate any hazards to the site. Satisfying these Conditions of Approval is for limited [City purpose] only and should not be relied on for design, geological or engineering purposes. Developer will comply with all requirements of Boise City Hillside Development Code Sections or submit evidence satisfactory to the Boise City Engineer that the proposed development is exempt from the requirements therein stated due to location, topography and/or the absence of adverse conditions associated with slope stability, ground water, erosion and sedimentation.If you would like to discuss this determination, please contact us at HillsideDrainage@cityofboise.org. Please include your application number and address in the subject line.
Aug. 6, 2026
Concept Review Complete: Engineering Preview
Aug. 6, 2026
Application Submittal: Online
Aug. 6, 2026
Application filed
Documents
Site plans
- Download Existing topographic survey
Preliminary topographic survey of the existing site improvements, observed May 27, 2026, with boundary, utility and elevation notes; no title report yet.
Aug. 6, 2026 · 1 page · 966 KB · PDS-Other Small Docs
- Download Site plan for residential remodel
Architect's site plan for a home remodel showing lot coverage, setbacks, square footage figures, and general construction notes.
Aug. 6, 2026 · 1 page · 366 KB · PDS-Other Small Docs
Project narrative
- Download Concept review summary for hillside addition
Planner's concept review summary for a 172-square-foot addition and two rebuilt decks on an existing single-family home, flagged as a Category II Hillside project requiring a geotechnical report and related technical…
Oct. 5, 2026 · 2 pages · 452 KB · PDS-Concept Review Summary Report
- Download Project description letter
Applicant's letter requesting a building permit for a 172 square foot residential addition, interior remodel, and rebuilding of two decks, one covered.
Aug. 6, 2026 · 1 page · 127 KB · PDS-Other Small Docs
Application
- Download Planning project application form
Application for a 172 square foot addition to an existing single-family home and rebuilding two decks disturbed during construction, in the R-1C zone.
Aug. 6, 2026 · 2 pages · 154 KB · PDS-Application
- Download Hillside project questionnaire
Public Works questionnaire asking whether the project involves new parcel lines, additions, new dwellings, driveways, deep grading, or retaining walls over 4 feet.
Aug. 6, 2026 · 1 page · 127 KB · PDS-Other Small Docs